Provider guides / Receiving and storage / Ridge Biologics, updated November 2026
Cryopreservation stops biological activity by cooling cells to very low temperatures so they can be stored and shipped. Done well, most cells survive. Done poorly, or interrupted along the way, many do not.
The cryoprotectant
Water inside a cell forms ice crystals as it freezes, and those crystals damage the cell. A cryoprotectant limits that damage. Dimethyl sulfoxide, or DMSO, is the most widely used, typically at 5 to 10 percent of the freezing solution. Formulations without DMSO also exist. The product information should state which is used.
Controlled rate freezing
Cells are cooled slowly, commonly about one degree Celsius per minute, so water can leave the cell before it freezes. Manufacturers use programmable freezers that record the cooling curve for each run.
Storage
Long term storage is usually in the vapor phase of liquid nitrogen, colder than minus 150 degrees Celsius. At those temperatures biological activity effectively stops. Warmer freezers allow slow change over time, which is why each product specifies its own storage condition and expiration.
Shipping
Product travels in a qualified shipper designed to hold temperature for a stated number of days, often with a temperature recorder inside. A brief warming event during transit can reduce viability even if the vial arrives frozen.
Thawing
Slow freezing and rapid thawing is the general rule. Each product comes with its own thaw instructions, and those instructions govern. Once thawed, a product should not be frozen again.
Related reading
This article is general education for licensed healthcare providers. It is not medical advice, it is not a claim about any product or clinical outcome, and it does not replace the instructions and documentation supplied with a specific product. See our Legal notices.